[1]朱健,赵均海,谭平,等.基于随机模拟的单层工业厂房全寿命期地震成本研究[J].地震工程与工程振动,2018,(01):051-64.[doi:10.13197/j.eeev.2018.01.51.zhuj.007]
 ZHU Jian,ZHAO Junhai,TAN Ping,et al.Seismic life-cycle loss estimation of single-story factory buildings[J].EARTHQUAKE ENGINEERING AND ENGINEERING DYNAMICS,2018,(01):051-64.[doi:10.13197/j.eeev.2018.01.51.zhuj.007]
点击复制

基于随机模拟的单层工业厂房全寿命期地震成本研究
分享到:

《地震工程与工程振动》[ISSN:/CN:]

卷:
期数:
2018年01期
页码:
051-64
栏目:
论文
出版日期:
2018-06-30

文章信息/Info

Title:
Seismic life-cycle loss estimation of single-story factory buildings
作者:
朱健12 赵均海1 谭平3 周福霖3
1. 长安大学 建筑工程学院, 陕西 西安 710064;
2. 宁夏大学 土木与水利工程学院, 宁夏 银川 750021;
3. 广州大学 工程抗震研究中心, 广东 广州 510405
Author(s):
ZHU Jian12 ZHAO Junhai1 TAN Ping3 ZHOU Fulin3
1. Department of Civil Engineering, Changan University, Xian 710064, China;
2. Department of Civil and Hydraulic Engineering. Ningxia University, Yinchuan 750021, China;
3. Earthquake Engineering Research and Test Center, Guangzhou University, Guangzhou 510405, China
关键词:
全寿命周期地震成本单层工业厂房钢筋混凝土排架结构增量动力分析蒙特卡洛样本法随机分析
Keywords:
seismic life-cycle costsingle-layer factory buildingsreinforced concrete bent structuresincremental dynamic analysisMonte Carlo samplingsstochastic analysis
分类号:
TH212;TH213.3
DOI:
10.13197/j.eeev.2018.01.51.zhuj.007
摘要:
依据中国建筑抗震设计规范(GB50011-2010)建立了我国西部具体地区的地震风险概率模型,基于IDA增量动力分析对该地区典型单层钢筋混凝土排架工业厂房结构承载力和地震易损性进行了分析计算,采用三参数分别表征排架厂房结构性和非结构性构件地震损伤并进一步加权计算了单层工业厂房全寿命期地震损失成本,计算中包括结构荷载、材料特征值、外加地震荷载等有关参数变量不确定性采用蒙特卡洛(Monte Carlo Sampling,MCS)随机样本予以考虑,研究得到了该地区单层排架工业厂房结构的地震巨灾保险费用统计值在12.78元~12.86元/年·m2,验证了技术分析路径的可行性,通过对统计结果值的特征分析,单层钢混排架结构厂房的地震年均成本直接费用CoV偏差在1.11-1.12%之间。
Abstract:
The seismic hazardous probability model of selected region in Western China is established based on China seismic code (GB500011-2010). The seismic life-cycle cost (SLCC) is a measure of the damage cost due to future earthquakes that will occur during the design life of a structure. So the seismic capacity of reinforced concrete factory buildings in multiple earthquake hazard levels is studied using nonlinear incremental dynamic analysis(IDA). We use 3 damage indices (DIs) whose values can be related to particular structural & nonstructural damage states in weighted calculation of SLCC of industrial buildings In order to take into account uncertainty on the mass, the material properties, the ground wave, the Monte Carlo sampling method is integrated into the IDA framework. The seismic catastrophe insurance premium of single-story factory buildings in selected area is between 12.78~12.86 yuan/m2 annually, and the same time, the Coefficient variance of results is only 1.11~1.12%.

参考文献/References:

[1] 国家减灾委员会科学技术部抗震救灾专家组,汶川地震灾害综合分析与评估[M].北京:科学出版社,2008:169. Earthquake relief expert group of Commission of science and technology department in National disaster reduction, Comprehensive analysis and evaluation of wenchuan earthquake disaster[M]. Beijing:Science press, 2008:169.(in Chinese)
[2] 新浪财经,地震三分钟,东方电气损失70亿.(2008-5-22).http://finance.sina.com.cn/stock/s/20080522/11384898390.shtml. Sina finance, Eastern Electronics loss 7 billion Yuan during We chuanEarthquake.(2008-5-22).http://finance.sina.com.cn/stock/s/20080522/11384898390.shtml. (in Chinese)
[3] 本刊专题研究小组, 东日本大地震特别报道之一:东日本大地震重击日本经济复苏[J].科技智囊,2011,5:22-37. Special research group, Special report No.1 of The eastern Japan earthquake:The east Japan earthquake pounded Japan’s economic recovery[J]. Science and technology intelligence,2011,5:22-37.(in Chinese)
[4] 腾讯财经, 我国建立巨灾保险制度三难题.(2014-3-11).http://new.qq.com/cmsn/20140311010758. Tencent finance,Three obstacles in construct of catastrophe insurance in China.(2014-3-11).http://new.qq.com/cmsn/20140311010758. (in Chinese)
[5] Alexandros Lamprou, Gaofeng Jia, Alexandros A. Taflanidis, Life-cycle seismic loss estimation and global sensitivity analysis based on stochastic ground motion modeling[J]. Engineering Structures, 2013, 54:192-206.
[6] 朱健.结构动力学原理与地震易损性分析[M],北京:科学出版社,2013. ZHU Jian. Structural dynamics and seismic vulnerability analysis[M], Beijing:Science Press, 2013.(in Chinese)
[7] Scholl R E, Seismic damage assessment for high-rise buildings, open-file report 81-031, US geological survey[J]. Menlo Park, CA,1980,143.
[8] Kustu O. Earthquake damage prediction for buildings using component test data[C]//Third U.S. National Conference on Earthquake Engineering, Charleston, South Carolina, Earthquake Engineering Research Institute, El Cerrito, CA, 1986, 2:1493-1504.
[9] Porter K A, Kennedy R P, Bachman R E. Creating fragility functions for performance-based earthquake engineering[J]. Earthquake Spectra, 2007, 23:471-89.
[10] Porter K A, Kiremidjian A S, LeGrue J S. Assembly-based vulnerability of buildings and its use in performance evaluation[J]. Earthquake Spectra. 2001,18:291-312.
[11] 中国建设部,建筑抗震设计规范(GB50011-2010)[S].北京:中国建筑工业出版社,2010. Ministry of Construction P.R.China. Code for seismic design of buildings (GB50011-2010)[S]. Beijing:China Construction Press Publication, 2010.(in Chinese)
[12] Fragiadakis M, Lagaros N D, Papadrakakis M. Performance based multi objective optimum design of steel structures considering life-cycle cost[J]. Struct Multidiscip Optimiz. 2006, 32:1-11.
[13] Kirch C A, Whiteman R V, Holmes W T. Hazus earthquake loss estimation methods[S]. Nat Hazards, 2006,32:1-11.
[14] Yuji Takahashi, Armen Der Kiureghian. Life-cycle cost analysis based on a renewal model of earthquake occurrences[J]. Earthquake Engng Struct. Dyn. 2004, 33:859-880.
[15] Christine A, Goulet, Curt B. Haselton, et al. Evaluation of the seismic performance of a code-conforming reinforced concrete frame building-from seismic hazard to collapse safety and economic losses[J]. Earthquake Engng Struct. Dyn.,2007, 36:1973-1997.
[16] Bora Gencturk. Life-cycle cost assessment of RC and ECC frames using structural optimization[J]. Earthquake Engineering & Structural Dynamics, 2013(42):61-79.
[17] Wen Y K, Kang Y J. Minimum building life-cycle cost design criteria. Ⅱ:Applications[J]. Journal of Structural Engineering (ASCE), 2001, 127(3):338-346.
[18] Liu M, Burns S A, Wen Y K. Optimal seismic design of steel frame buildings based on life cycle cost considerations[J]. Earthquake Engineering and Structural Dynamics, 2003(32):1313-1332.
[19] 唐玉,郑七振,楼梦麟. 基于"投资-效益"准则的抗震性能目标优化决策[J].同济大学学报:自然科学版, 2012, 40(11):1613-1619. TANG Yu, ZHEN Qizhen, LOU Menglin. Optimization of seismic performance objectives based on cost effectiveness criterion[J]. Journal of Tongji University, 2012, 40(11):1613-1619.(in Chinese)
[20] Ramirez C M, et al. Expected earthquake damage and repair costs in reinforced concrete frame buildings[J]. Earthquake Engineering & Structural Dynamics, 2012,41(11):1455-1475.
[21] Li Gang, Jiang Yi, Yang Di xiong.Modified modal pushover based seismic optimum design for steel structures considering life-cycle cost[J]. Structural and Multidisciplinary optimization, 2012, 45(6):861-874.
[22] Dong-Woo Seo. Luca Caracoglia, Estimating life-cycle monetary losses due to wind hazards:Fragility analysis of long-span bridges[J]. Engineering Structures, 2013(56):1593-1606.
[23] Kevin K F, Wong, John L. Harris. Seismic fragility and cost analyses of actively controlled structures[J]. Struct. Design Tall Spec. Build,2013(22):569-583.
[24] Ghobarah A. On drift limits associated with different damage levels[C]//In:Proceedings of the international workshop on performance-based seismic design:June 28-July 1.2004.
[25] Elenas A, Meskouris K. Correlation study between seismic acceleration parameters and damage indices of structures[J]. Eng Struct, 2001,23:698-704.
[26] ATC-13. Earthquake damage evaluation data for California[S]. Redwood City. CA:Applied Technology Council, 1985.
[27] FEMA 227. A benefit-cost model for the seismic rehabilitation of buildings[S]. Washington, DC:Federal Emergency Management Agency, Building Seismic Safety Council:1992.
[28] Lagaros N D, Mitropoulou C C. The effect of uncertainties in seismic loss estimation of steel and reinforced concrete composite buildings[J]. Structure and Infrastructure Engineering, 2013, 9(21):546-556.
[29] 黄兴富, 酆少英,等. 银川盆地构造发展-深地震反射剖面揭示浅部地质与深部构造的联系[J]. 地质科学,2016, 51(1):53-66. HUANG Xinfu, FENG shaoying, et al. Development of the yin-chuan basin:deep seismic reflection profile revealed the linkages between shallow geology and deep structures[J]. Chinese Journal of Geology. 2016, 51(1):53-66. (in Chinese)
[30] FEMA-350, Recommended seismic design criteria for new steel moment-frame buildings[S]. Washington DC:Federal Emergency Management Agency. 2000.
[31] Mander J B, Priestley M J N, Park R. Theoretical stress-strain model for confined concrete[J]. Journal of Structural Engineering, 1988,114(8):1804-1826.
[32] Martinez-Rueda J E, Elnashai A S. Confined concrete model under cyclic load[J]. Materials and Structures,1997, 30(197):139-147.
[33] Menegotto M, Pinto P E. Method of analysis for cyclically loaded R.C. plane frames including changes in geometry and non-elastic behavior of elements under combined normal force and bending[C]//Symposium on the Resistance and Ultimate Deformability of Structures Acted on by Well Defined Repeated Loads, International Association for Bridge and Structural Engineering, Zurich, Switzerland, 1973:15-22.

相似文献/References:

[1]田洁,姚谦峰,王克成.单层工业厂房-TMD减震控制系统研究[J].地震工程与工程振动,2005,(01):138.
 Tian Jie,Yao Qianfeng,Wang Kecheng.Study on seismic control of the single-storey industrial building with tuned mass damping (TMD)[J].EARTHQUAKE ENGINEERING AND ENGINEERING DYNAMICS,2005,(01):138.

备注/Memo

备注/Memo:
收稿日期:2017-04-06;改回日期:2017-09-17。
基金项目:国家自然科学基金项目(51468050)
作者简介:朱健(1975-),男,教授,博士,主要从事土木工程防震减灾及地震巨灾保险研究.E-mail:zhujian@nxu.edu.cn
更新日期/Last Update: 1900-01-01