[1]李黎,何先龙,贾行建.一种新的大坝强震动监测系统[J].地震工程与工程振动,2018,(05):146-152.[doi:10.13197/j.eeev.2018.05.146.lil.017]
 LI Li,HE Xianlong,JIA Xingjian.A new strong motion monitoring system of dam[J].EARTHQUAKE ENGINEERING AND ENGINEERING DYNAMICS,2018,(05):146-152.[doi:10.13197/j.eeev.2018.05.146.lil.017]
点击复制

一种新的大坝强震动监测系统
分享到:

《地震工程与工程振动》[ISSN:/CN:]

卷:
期数:
2018年05
页码:
146-152
栏目:
论文
出版日期:
2018-10-31

文章信息/Info

Title:
A new strong motion monitoring system of dam
作者:
李黎1 何先龙2 贾行建2
1. 国投云南大朝山水电有限公司, 云南 昆明 650000;
2. 中国地震局工程力学研究所, 中国地震局地震工程与工程振动重点实验室, 黑龙江 哈尔滨 150080
Author(s):
LI Li1 HE Xianlong2 JIA Xingjian2
1. Investment in Yunnan Dachaoshan Hydropower Co., Ltd, Kunming 650000, China;
2. Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration, Harbin 150080, China
关键词:
大坝强震动监测大坝震害快速评估工频干扰和误触发问题强震动事件自动处理
Keywords:
dam strong motion monitoringdam damage rapid assessmentproblem of power frequency interference and false triggeringautomatic handling of strong motion events
分类号:
P315.9
DOI:
10.13197/j.eeev.2018.05.146.lil.017
摘要:
水电站大坝强震动响应特性是大坝震害快速评估和制定震后紧急处置措施的重要依据,也是大坝安全监测系统的重要部分,但是现有的大坝强震监测监测系统存在设备和维护成本高、自动化分析能力不强、参数速报不及时等缺陷。本文设计了一种新的大坝强震动监测系统:首先设计了一种15通道式强震动记录仪和一种防水型加速度计;然后针对常见的工频干扰和误触发问题,提出了一种实用的有效解决方法;最后设计了一套自动分析能力强、速报及时、管理便捷化的大坝强震动数据远程接收与在线分析软件。相比传统的分布式强震动监测系统,此新系统具有设备成本低、无人值守、强震动事件自动处理、误触发概率小、烈度等参数速报及时等特点,且通过短信、邮件实现了与智能手机的联动。此新系统已布设于大朝山、功果桥、乌东德等多个水电站,且最近多次强震事件验证了此系统的主要特点和可靠性。
Abstract:
Strong vibration response characteristics of dam in hydropower station is an important basis for rapid assessment of dam damage and formulation of emergency measures after earthquake, it is also an important part of dam safety monitoring system. However, the existing strong dam monitoring system has some defects,such as high equipment and maintenance costs、automation analysis ability is not strong、the parameter is not timely reporting and so on. A new monitoring system is designed in this paper:first of all, we designed a 15 channel strong motion recorder and a waterproof accelerometer. Then, a practical and effective solution is proposed for the common power frequency interference and error triggering. Finally, we design a set of remote data receiving and on-line analysis software,which can automatic analysis and report timely, it is easy to management too.Compared to the traditional distributed strong motion monitoring system,This new system has the advantages of low equipment cost, unattended, automatic processing of strong motion events,small probability of false triggering, the parameters such as intensity can be timely reported,and it can also achieve the interaction with smart phones through SMS, e-mail.This new system has been deployed in a plurality of hydro power station,such as Dachaoshan, Gongguoqiao, Wudongde etc. and recently several strong earthquake event have verified the main characteristics and reliability of the system.

参考文献/References:

[1] DL/T 5416-2009水工建筑物强震动安全监测技术规范[S]. 北京:中国电力出版社,2009. DL/T 5416-2009 Technical Specification for Safety Monitoring of Strong Vibration of Hydraulic Structures[S]. Beijing:China Electric Power Press,2009.(in Chinese)
[2] NB 35047-2015水电工程水工建筑物抗震设计规范[S]. 北京:中国电力出版社,2015. NB 35047-2015 Code for Seismic Design of Hydraulic Structures in Hydro Power Projects[S]. Beijing:China Electric Power Press,2015.(in Chinese)
[3] 邹浩. 大坝振动台模型试验的损伤检测方法研究[D]. 大连:大连理工大学, 2015. ZOU Hao. Research on Power stationage detection method of Power station shaking table model test[D]. Dalian:Dalian University of Technology, 2015.(in Chinese)
[4] 刘福海. 土石坝地震破坏机理振动台试验研究[D]. 大连:大连理工大学, 2012. LIU Fuhai. Shaking table test study on seismic failure mechanism of earth rock Power station[D]. Dalian:Dalian University of Technology, 2012.(in Chinese)
[5] 许光, 苏克忠, 郭永刚,等. 国内水工建筑物强震安全监测技术进展[J]. 水电与抽水蓄能, 2012, 36(2):63-67. XU Guang, SU Kezhong, GUO Yonggang,et al. Progress of seismic safety monitoring technology for hydraulic structures in China[J]. Hydro Power and Pumped Storage, 2012, 36(2):63-67.(in Chinese)
[6] 苏克忠,张立飞,朱栗武,等.大坝强震安全监测[M].北京:中国水利水电出版社,1996 SU Kezhong,ZHANG Lifei,ZHU Liwu,et al.Power station strong earthquake safety monitoring[M].Beijing:China Water Conservancy and Hydropower Press,1996.(in Chinese)
[7] 张凡, 闫俊岗, 李锐,等. 强震观测在小浪底水利枢纽大坝监测中的应用[J]. 华北地震科学, 2010, 28(4):57-59. ZHANG Fan, YAN Jungang,LI Rui,et al. Application of strong seismic oscillation monitoring observation in Power station monitoring of Xiaolangdi Power station water control project[J]. North China Earthquake Sciences, 2010, 28(4):57-59.(in Chinese)
[8] 丁小龙. 龙羊峡水电站大坝振动试验研究[J]. 陕西电力, 2010, 38(3):30-33. DING Xiaolong. Experimental study on power station vibration of longyangxia hydropower station[J]. Shaanxi Electric Power, 2010, 38(3):30-33.(in Chinese)
[9] 严根华. 大坝泄水闸门结构流激振动监测及强烈振动控制技术研究[J]. 大坝与安全, 2016(3):44-54. YAN Genhua. Study on flow induced vibration monitoring and strong vibration control technology of Power Station Sluice Gate Structure[J]. Power station and safety, 2016(3):44-54.(in Chinese)
[10] 杨利, 杨少华. 强震观测在功果桥水电站大坝监测中的应用[J]. 水电与抽水蓄能, 2013, 37(3):43-46. YANG Li,YANG Shaohua. Application of strong seismic oscillation monitoring observation in Power station monitoring of power station[J]. Hydro Power and Pumped Storage, 2013, 37(3):43-46.(in Chinese)
[11] 李彩华. 力平衡加速度传感器设计分析[J]. 传感器与微系统, 2005, 24(8):46-48. LI Caihua. Design and analysis of force balance acceleration sensor[J]. Sensors and Microsystems, 2005, 24(8):46-48.(in Chinese)

备注/Memo

备注/Memo:
收稿日期:2017-12-10;改回日期:2018-03-15。
基金项目:国家自然青年科学基金项目(51508536)
作者简介:李黎(1972-),男,高级工程师,主要从事大坝安全管理、安全监测资料分析.E-mail:468050678@qq.com
通讯作者:何先龙(1981-),男,副研究员,博士,主要从事地震工程与工程振动监测技术的研究.E-mail:2424186@qq.com